JC190GG
- Model: JC190GG
Unit has stopped cooling or is not cooling enough?
1. Check ventilation around the fridge. You need 10mm at sides and top with 50mm at the rear.
2. The unit cannot have another ‘door’ in front of the fridge door, this is incorrect installation and voids warranty.
3. The unit must be 100% away from sunlight and out of the weather, this is incorrect installation and voids warranty.
4. Unit is a commercial indoors type, so 32°c ambient is the maximum the outside temperature can be for normal operation.
5. Check compressor definitely comes ON.
6. Check inner fan is going and that there is NO ice buildup on the inner rear wall.
7. Check if you can feel a slight breeze coming out of grill at the front when the compressor is on.
8. Check the temperature that you have the fridge set on. If the fridge is set on 2°c, it will cycle between 2 - 6°c and keep your drinks around 4°c.
I have condensation forming on my glass doors?
1. Check Heated door switches are on.
2. Check sunlight exposure is 0% at any point of the day.