BCH70B

My door sticks when I try to close it?

Over time the unit's door may drop at one corner, which can cause it to contact the lock plate beneath the door. The doors have a top and bottom hinge, both capable of slight adjustments to re-align the door, or simply apply mild force on the door locking plate downwards to allow the door to close.

The LED light is not working?

  1. Check the switch is set to the 'on' position.
  2. Check the connection to the LED light is secure — remove the light from the roof cavity by prying downwards.

The inner rear wall is icing up?

  1. Inner fan has failed.
  2. High ambient humidity can cause excess ice and then create excess water in the drip tray to evaporate.
  3. Small gas leak — this may show up as a lot of ice at one corner of the cold plate inside the fridge.
  4. Thermostat is set too high and the unit is getting minimal usage. Defrost the fridge overnight and set the temperature lower.

My fridge has become noisy?

  1. Check the inner fan (if applicable) — a worn or failed fan bearing can cause excessive noise.
  2. Check the compressor mounting bolts are secure and the compressor is level.
    Internal buzzing, clunking or squealing sounds will indicate a worn/failing compressor.

My fridge has stopped cooling or is not cooling enough?

  1. Check to ensure that you have the correct ventilation, as per below.
    Each Side: 20mm
    Top: 20mm
    Rear: 100mm
  2. The unit cannot have another 'door' in front of the fridge door — this is incorrect installation and voids warranty.
  3. The unit must be completely protected from sunlight and weather — this is incorrect installation and voids warranty.
  4. Check the compressor engages and runs quietly.
  5. Check the thermostat setting — higher numbers are colder settings.